Terumo Interventional Systems Announces Commercial Availability of Its ROADSAVER™ Carotid Stent System
– Innovative, dual-layer micromesh, closed-cell stent with the flexibility of an open-cell stent for maximizing clinical outcomes in carotid artery stenting procedures –
ROADSAVER Stent System is the only carotid artery stenting (CAS) device with an innovative, dual-layer micromesh. It is designed as a closed-cell stent with the flexibility of an open-cell stent, providing increased flexibility and wall apposition in complex anatomies. It is also the first dual-layer micromesh carotid stent approved in
Available in sizes from 5 to 10 mm in width and 22 to 47 mm in length, ROADSAVER Stent System has a rapid-exchange shaft length of 143 cm. It is also fully re-sheathable and repositionable – even after 50% of the stent's length is deployed. Another important feature is the product's low-profile 5Fr design, which enhances its crossability.
"ROADSAVER Stent System is yet another example of our unrelenting pursuit of achieving better outcomes for patients," said
"An inner micromesh layer with a pore size four-times smaller than any carotid stent which provides sustained embolic protection makes the ROADSAVER Stent System a leading technology in the evolution of CAS," said
Limited market release of the ROADSAVER Carotid Stent System is planned for summer 2025, with full market release anticipated in fall 2025.
About Terumo Interventional Systems
Terumo Interventional Systems (TIS), a division of Terumo Corporation, is a market leader in minimally invasive entry site management, lesion access, and therapeutic intervention. TIS offers a complete, solution-based product portfolio used in advanced coronary, peripheral and endovascular treatments with strategic initiatives in Transradial Access, Complex Coronary Intervention, Peripheral Artery Disease and Embolotherapy. TIS combines innovative research and development with a deep market understanding to create a pipeline of industry-leading devices that deliver clinical value, economic benefit, and enhanced patient outcomes.
About Terumo
Terumo (TSE: 4543) is a global leader in medical technology and has been committed to "Contributing to Society through Healthcare" for over 100 years. Based in
ROADSAVER
INDICATIONS FOR USE
The Roadsaver Carotid Stent System, when used in conjunction with the Nanoparasol Embolic Protection System (EPS), is indicated for the treatment of carotid artery stenosis in patients with elevated risk for adverse events following carotid endarterectomy and meet the criteria outlined below:
- Patients who have either de novo atherosclerotic or post endarterectomy restenotic lesion(s) in the internal carotid arteries or at the carotid bifurcation with ≥50% stenosis if symptomatic or ≥80% stenosis if asymptomatic (both defined by angiography),
AND - Patients having a vessel with reference diameters between 3.5 mm and 9.0 mm at the target lesion.
CONTRAINDICATIONS
The Roadsaver Carotid Stent System is contraindicated for use in:
- Patients in whom anticoagulant, antiplatelet therapy or thrombolytic drugs are contraindicated
- Patients with known hypersensitivity to nickel-titanium
- Patients with severe vascular tortuosity or anatomy that would preclude the safe introduction of a guide catheter, sheath, embolic protection system, or stent system
- Patients with uncorrected bleeding disorders
- Lesions in the ostium of the common carotid artery
- Carotid vessel with
NANOPARASOL EPS
INDICATIONS FOR USE
The Nanoparasol EPS is indicated for use as a guidewire to contain and remove embolic material (thrombus/debris) while performing angioplasty and stenting procedures in carotid arteries. The diameter of the artery at the site of the filter placement should be between 3.0 and 6.5 mm.
CONTRAINDICATIONS
The Nanoparasol EPS is contraindicated for use in:
- Patients in whom anticoagulant, antiplatelet therapy or thrombolytic drugs is contraindicated
- Patients with known hypersensitivity to nickel-titanium
- Patients with severe vascular tortuosity or anatomy that would preclude the landing zone requirement or the
safe introduction of a guide wire, guide catheter, introducer sheath, an embolic protection device, delivery
catheter, or retrieval catheter - Patients with uncorrected bleeding disorders
- Lesions in the ostium of the common carotid artery
RX ONLY. Refer to the product labels and package insert for complete contraindications, warnings, precautions, potential complications, and instructions for use.
Manufacturer: Terumo Neuro, 35 Enterprise,
Distributed by Terumo Medical Corporation,
©2025 Terumo Medical Corporation.
All brand names are trademarks or registered trademarks owned by TERUMO CORPORATION, its affiliates, or unrelated third parties.
View original content to download multimedia:https://www.prnewswire.com/news-releases/terumo-interventional-systems-announces-commercial-availability-of-its-roadsaver-carotid-stent-system-302466149.html
SOURCE Terumo Interventional Systems
Serious News for Serious Traders! Try StreetInsider.com Premium Free!
You May Also Be Interested In
- Fundraise Up Launches AI Visibility Assessment to Help Nonprofits Prepare for Agentic Giving
- JFL Credit Partners with Powerhouse Engines to Launch Engine Investment Program
- Chelten House Names Jason Dabrow CEO, Ushering in Fourth Generation of Family Leadership
Create E-mail Alert Related Categories
PRNewswire, Press ReleasesRelated Entities
FDASign up for StreetInsider Free!
Receive full access to all new and archived articles, unlimited portfolio tracking, e-mail alerts, custom newswires and RSS feeds - and more!



Tweet
Share