Reverse Hip Replacement System Unveiled at Global Orthopedic Surgery Meeting
OrthoDome Forum Features a Video of the Reverse HRS Hip Replacement Procedure;
Presentation also Features Five-Year Radiostereometric Analysis and
Patient Reported Outcome Measures of the Reverse HRS
"We are extremely excited that the Reverse HRS was featured at AAOS in the OrthoDome with a video of an actual hip replacement surgery narrated by Dr.
The AAOS OrthoDome surgical video and live narration was led by
"Total hip arthroplasty is one of the most common joint replacement procedures conducted around the world and can benefit from device improvement and innovation," said
Reverse HRS Registrational Trial Underway
In 2023, Hip Innovation Technology launched its pivotal clinical research trial under an FDA approved Investigational Device Exemption (IDE). The IDE Study is being conducted to determine the safety and effectiveness of the HIT Reverse HRS in Primary Total Hip Arthroplasty (THA). Safety will be assessed through the collection of device-related adverse events and patient quality of life metrics. Effectiveness will be evaluated using clinical, radiologic, and patient-reported outcomes.
Previous RSA and Patient Outcomes Data
The Bone & Joint Open journal, recently published the article, "Radiostereometric analysis and clinical outcomes of a novel reverse total hip system at two years."
This publication demonstrated that the Reverse HRS delivered excellent fixation with a predicted low risk of revision at ten years, mean migration below the level of radiostereometric analysis (RSA) detection for both the femoral and acetabular components, and high rates of patient satisfaction including no patients reporting symptoms consistent with soft-tissue impingement within the articulation and no symptoms consistent with adverse reaction to metal debris.
Hip replacement surgery, or total hip arthroplasty, is one of the most common joint replacement procedures done in
HIT has extensively tested the Reverse HRS in over 90 standard and unique pre-clinical experiments to assess the product safety and clinical benefits anticipated by the unique system design.
About the Reverse HRS
The Reverse HRS is a Metal-on-Polyethylene reverse geometry hip prosthesis designed to improve stability at extended ranges of motion and reduce the risk of dislocation. Like most conventional systems, the Reverse HRS consists of a femoral stem, an acetabular cup and a cobalt-chrome ball that articulates within a polyethylene liner. Unlike existing total hip replacement systems, the ball is placed on a trunnion within the acetabular cup instead of the femoral stem, and the polyethylene liner is attached to a femoral cup, which then attaches to the femoral stem, as opposed to the polyethylene liner being attached to the acetabular cup. This technological difference does not change the center of rotation of the Reverse HRS and it remains similar to a normal physiological hip, or a well-positioned traditional Total Hip Arthroplasty. The advanced Reverse HRS implant is designed to provide greater range of motion in all planes, enhanced hip stability, and to reduce the risk of dislocation. Importantly, the Reverse HRS also provides variability of component placement including higher abduction angles and anteversion of the acetabular cup. The femoral cup articulates around the acetabular ball and overlaps with the acetabular cup as the hip undergoes flexion-extension, abduction-adduction and internal-external rotation. This forgiving design may compensate for suboptimal component positioning which may provide benefits such as extended range of motion, hip stability and reduced likelihood of impingement. The Reverse HRS is designed to uncouple the relationship between component placement, wear and stability. This unique implant design of the Reverse HRS provides optimal surface area contact between the acetabular ball and femoral cup, which may eliminate edge loading. Elimination of edge loading may provide benefits that include reduced high-contact stresses, decreased implant wear and uniform wear, which minimizes generation of wear debris and associated concerns related to osteolysis.
About Hip Innovation Technology, LLC
Headquartered in
For more information, visit www.hipinnovationtechnology.com.
Contact:
JFK Communications, Inc.
(609) 456-0822
[email protected]
View original content:https://www.prnewswire.com/news-releases/reverse-hip-replacement-system-unveiled-at-global-orthopedic-surgery-meeting-302063376.html
SOURCE Hip Innovation Technology, LLC
Serious News for Serious Traders! Try StreetInsider.com Premium Free!
You May Also Be Interested In
- KB HOME OPENS BRIGHTON CROSSINGS, A NEW COMMUNITY PRICED FROM THE $460Ks WITHIN A DESIRABLE BRIGHTON, COLORADO MASTER PLAN
- Citizens Commission on Human Rights International Releases White Paper on Antidepressants and Psychiatric Drug Reform
- Chainlink Price Prediction Lands $200 Bank Target but Pepeto Presale Is Already Outrunning It
Create E-mail Alert Related Categories
PRNewswire, Press ReleasesRelated Entities
FDASign up for StreetInsider Free!
Receive full access to all new and archived articles, unlimited portfolio tracking, e-mail alerts, custom newswires and RSS feeds - and more!



Tweet
Share